Compressors

Data sheet hydraulic compressor
mod. B

1

GENERAL

1.1 NO. OF UNITS : 1 DRIVER: Electric motor
2

OPERATING CONDITION

2.1 Service/Stage : continuos / 2-3-4 stage
2.2 Gas Handled : Natural Gas
2.3 molecular weight at intake (avg.) 0.68-0.82 kg/m3
2.4 Cp/Cv at intake/compressibility Factor 1.30:1.40 / 0.98:0.97
2.5 Drive arrangement : axial connection
2.6 Standard Conditions referred to: Standard Atmospheric pressure (1.033 Kg/cm² abs) and Temperature of 15°C
3

SITE CONDITIONS

3.1 Installation : not direct exposed to weather
3.2 Site Ambient Temp. (°C): Min -20 °C Max +40 °C
3.3 Area Classification : Dangerous Area
4

APPLICABLE CODES & SPECIFICATIONS

4.1 1 Compressor EUROPEAN NORM P.E.D.

italian NORM D.P.R. 547/55

“CLASS 3” ACCORDING TO 94/9/CE (ATEX) ED

It is SUITABLE At use In Ex "Zone 2" Accordingly To EN 60079-10 (CEI 31-30)

2 MACHINES IN PRESSURE EUROPEAN NORM P.E.D.
3 SAFETY VALVES EUROPEAN NORM P.E.D

D.M. 24.5.02 - D.M. 28.6.02

4 GAS PIPING AND FITTINGS D.M 24.11.84 parte prima - sez. II°

D.M. 24.5.02 - D.M. 28.6.02

DIN 2413

SAE J 514

5 ELECTRICAL EQUIPMENTS EUROPEAN NORMS

CEI EN 60079-10/CEI EN 60079-14/CEI

EN 60204-1/ CEI EN 60439-1

ATEX STANDARD

6 VERIFICATION AND TEST D.M 24.11.84

D.M. 24.5.02 - D.M. 28.6.02

SAFE Std

6

PIPING AND INSTRUMENTATION DIAGRAM

6.1

Type of cooling

  AIR-WATER AIR-GAS
  number of stage number of stage
  2 2
Plant gas G-598 G-1120
Lubrication plant H-223 H-223
Cooling plant I-303 G-1120 - H-223
7

COOLING SYSTEM

7.1 2nd stage cylinder Air - water
Oil Water
Gas Air - water